National Repository of Grey Literature 2 records found  Search took 0.01 seconds. 
Office and logictic building
Navrátil, Ondřej ; Ing. Michal Štrba. Ph.D. (referee) ; Pilgr, Milan (advisor)
Design of a steel supporting structure for one-storeyed hall based on ground plan of 60 x 80 m, clear height 10 m and total height 13,3 m. In the front part there is along the whole widht designed two-storeyed skeleton structure penetrating into the hall. From the second floor rods supported frontal part which exceeds ground plan by 2 m and on the right side is closed by pre-set cylindric structure with radius 8,6 m which covers the right frontal corner of building. The cylindric structure is around its perimeter distanced max 3,6 m from hall grand plan and is supported by posts. Both spaces had saddle roof with 8% slant, gutter edge in height 11,6 m, top line in height 12,8 m. Walls are around perimeter closed by horizontal atic in height of 13,3 m. Shape and dimensional design, load specification – stady, utility, climacic load. Calculation of imide forces and further static dimensioning of the main supporting elements and selected details. Elaboration of design documentation (dosposition, production drawing of the anchorage plan, details definited by project supervizor).
Office and logictic building
Navrátil, Ondřej ; Ing. Michal Štrba. Ph.D. (referee) ; Pilgr, Milan (advisor)
Design of a steel supporting structure for one-storeyed hall based on ground plan of 60 x 80 m, clear height 10 m and total height 13,3 m. In the front part there is along the whole widht designed two-storeyed skeleton structure penetrating into the hall. From the second floor rods supported frontal part which exceeds ground plan by 2 m and on the right side is closed by pre-set cylindric structure with radius 8,6 m which covers the right frontal corner of building. The cylindric structure is around its perimeter distanced max 3,6 m from hall grand plan and is supported by posts. Both spaces had saddle roof with 8% slant, gutter edge in height 11,6 m, top line in height 12,8 m. Walls are around perimeter closed by horizontal atic in height of 13,3 m. Shape and dimensional design, load specification – stady, utility, climacic load. Calculation of imide forces and further static dimensioning of the main supporting elements and selected details. Elaboration of design documentation (dosposition, production drawing of the anchorage plan, details definited by project supervizor).

Interested in being notified about new results for this query?
Subscribe to the RSS feed.